A few days ago I deployed a two-node proxmox ve cluster. It worked fine at first, but after a day, when I logged in to the dell r720 host over ssh, I found the shell responding very slowly, and going into the linux container on it was even worse — every time I typed a command, zsh would freeze for quite a while.

I thought it was a problem with zsh, so I switched to bash and fish, but they were only slightly better. Opening a local file with vim was also very slow — could the disk be the problem? The system disk on this dell host is a West Digital SN750 1T, which by all accounts shouldn’t be slow, so I ran a test:

1
time dd if=/dev/zero of=tst.out bs=4M count=256

I had no idea until I tested it, and the result gave me a shock:

1
2
3
256+0 records in
256+0 records out
1073741824 bytes (1.1 GB, 1.0 GiB) copied, 42.666 s, 24 MB/s

That was abnormally slow. Neither sudo dmesg | grep -i error nor sudo grep -i 'error' /var/log/syslog revealed any problem. It is the system disk and hadn’t been touched since installation.

I tried the good old reboot, and found that booting into the system took a very long time. Checking with smarttools showed no bad sectors and no errors at all. I was frustrated. After searching on google and bing for a long time without much to show, one answer mentioned in passing that it might be an apm power management issue and that hdparm should be used to inspect the settings. I looked for a long time, but it had no effect on my disk and just threw errors.

After thinking for a while, I realized I had been searching for ssd, so I switched the keyword to nvme and searched again.

I found a new tool: nvme-ctl. Someone said to use it to check the nvme power management configuration. I checked its manpage and saw that nvme get-feature is used to inspect power management, but it didn’t say what the --feature-id parameter should be, so I kept looking.

On nvme’s official site I found one: feature-id=0x02 refers to power management. I tried running it:

1
sudo nvme get-feature -f 0x02  /dev/nvme0 -H

And got the result:

1
2
3
get-feature:0x2 (Power Management), Current value:0x000003
        Workload Hint (WH): 0 - No Workload
        Power State   (PS): 3

There was a result, but what exactly is 0x03? I remembered that when I checked earlier with smarttools there seemed to be a list of power states, so I tried it, and sure enough there was one:

1
2
3
4
5
6
7
Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +     3.50W    2.90W       -    0  0  0  0        0       0
 1 +     2.70W    1.80W       -    0  0  0  0        0       0
 2 +     1.90W    1.50W       -    0  0  0  0        0       0
 3 -   0.0200W       -        -    3  3  3  3     3900   11000
 4 -   0.0050W       -        -    4  4  4  4     5000   39000

As you can see, 0x03 is drastically different from the previous ones — it’s basically asleep. I set it to 0x02 to try:

1
sudo nvme set-feature /dev/nvme0 -f 0x02 --value=2

The result was satisfying:

1
2
3
4
4096+0 records in
4096+0 records out
16777216 bytes (17 MB, 16 MiB) copied, 0.0757074 s, 222 MB/s
dd if=/dev/zero of=tst.out bs=4k count=4096  0.00s user 0.03s system 39% cpu 0.080 total

222 MB/s — finally it felt like real read/write speed. I changed it to 0x01:

1
sudo nvme set-feature /dev/nvme0 -f 0x02 --value=0x01

Result:

1
2
3
4
256+0 records in
256+0 records out
1073741824 bytes (1.1 GB, 1.0 GiB) copied, 2.3109 s, 465 MB/s
dd if=/dev/zero of=tst.out bs=4M count=256  0.00s user 1.43s system 57% cpu 2.495 total

After struggling with this all evening and about to reinstall the system, I found the answer by talking step by step with new bing’s chat gpt. As capable as chat gpt is, asking the right question matters too — it doesn’t have the human knack for guessing.

At last, speed freedom achieved.